2024/03/20 Product Information Project Reference Generator, Welder, Air Compressor
Generator 10 kVA to 1250 kVA for rent in Vietnam
目次
- We have many models of Generators for rent in Hanoi, Hung Yen, Bac Ninh, Bac Giang, Hai Phong, Ha Nam, Ha Tinh, Da Nang, Quang Nam, HCM city, Dongnai, Binh Duong, Vung Tau… and other locations.
- Why should you rent the Generator?
- Where to rent Generators in Vietnam?
- Important things that you need to know when choosing a Generator rental supplier
- Rental Generator price in Vietnam
- Our Generator models for rent
- Shindaiwa DGW310MC (9.9 kVA)
- Denyo DCA25ESK and Airman SDG25 (20 kVA)
- Denyo DCA45ESI (37 kVA)
- Airman SDG45 (37 kVA)
- Denyo DCA60ESI (50 kVA)
- Airman SDG60S (50 kVA)
- Denyo DCA100ESI (80 kVA)
- Airman SDG100S (80 kVA)
- Denyo DCA125SPK3 (100 kVA)
- Airman SDG150S (125 kVA)
- Denyo DCA150 (125 kVA)
- Airman SDG220S (200 kVA)
- Denyo DCA220ESK (200 kVA)
- Denyo DCA300SPK3 (270 kVA)
- Airman SDG300S (270 kVA)
- Airman SDG400S (350 kVA)
- Denyo DCA400SPMII (350 kVA)
- Denyo DCA600SPK (554 kVA) / DCA610SPM (554 kVA)
- Denyo DCA800SPK (700kVA)
- UPR1250 (1250 kVA)
- Some photos of the projects that used NISHIO’s Generator
We have many models of Generators for rent in Hanoi, Hung Yen, Bac Ninh, Bac Giang, Hai Phong, Ha Nam, Ha Tinh, Da Nang, Quang Nam, HCM city, Dongnai, Binh Duong, Vung Tau… and other locations.
Why should you rent the Generator?
- The use of GENERATOR usually happens during the summer period at factories, workshops… or the early stages of construction projects. Meanwhile, investment costs (generator prices) are very high. Understanding this difficulty, the Generator rental service has begun to develop and expand in Vietnam.
- RENTAL COST INCLUDES MAINTENANCE BY A HIGH-SKILLED MECHANIC TEAM. For these reasons, many businesses often choose to rent a generator in case of need instead of buying a new one.
- The situation of power cuts in the summer in the coming years will likely become much more serious than in previous years. Therefore, businesses need to have a plan to prevent power shortages right now. One of those options is to have a list ofGENERATOR RENTAL providers. When there is a power outage, you can contact the supplier immediately to arrange transportation..
- After you have finished using the Generator, you will return it to the supplier, without wasting space and worrying about maintenance the Generator if not used for a long time.
Where to rent Generators in Vietnam?
There are so many companies which suppling Generator rental service in Vietnam. However, you should choose carefully because Generator must be in a good condition. NISHIO RENT ALL VIETNAM COMPANY LIMITED is honored to be the leading generator rental service provider in Vietnam for both construction and industrial projects nationwide.
NISHIO supplies Generators to Industrial Parks and Construction Projects in Hanoi, Bac Ninh, Bac Giang, Hai Phong, Vinh Phuc, Phu Tho, Hai Duong, Quang Nam, Quang Ngai, Ho Chi Minh, Dong Nai. Nai, Binh Duong, Vung Tau,… and many other provinces. With a full range of large, medium and small capacity generators, we are confident that we will bring maximum benefits and safety to all customers.
Generator is one of our major equipment. NISHIO commits to only renting Generators in a condition that ensures safety and quality.
We have been direct partners of DENYO, AIRMAN, GENERAC… for more than 60 years – the oldest and most prestigious Generator brands in the world. Customers can feel secure when using generators that Nishio provides because they always have complete records and documents of origin of the equipment.
Read more “DENYO organized a generator training course for NISHIO mechanic”
NISHIO has the headquarters and main equipment warehouse in Thach That IZ, Hanoi and other branches in three regions. We are proud to be the largest generator supplier in Vietnam.
NISHIO offices address:
- North Office (Hanoi Head Office): Lot CN3*, Thach That – Quoc Oai Industrial Park, Phung Xa Ward, Thach That District, Hanoi. (Hotline 02433940471)
- South Office (HCM Office): No. 990 Hanoi Highway, Quarter 2, Binh Da Ward, Bien Hoa City, Dong Nai Province. (Hotline 02513683224)
- Other branches: Hai Phong, Da Nang, Quang Nam
Photo: High-quality Generators at Hanoi
Are you worry about the power outage situation in this summer? If you need to find an emergency generator to rent, contact us!
When there is an unexpected power outage, just pick up the phone and call our Hotline number or contact us via the website, we will transfer your information to the sales department and quote you the fastest. Then, the Generator will be thoroughly inspected before being delivered to your side. Our mechanics will also provide guidance until customers can clearly grasp the operating rules.
During the process of using our Generator, if it has a problem arises and needs urgent repair, a mechanic will immediately receive your information and come to check directly. The monthly machine maintenance schedule will also be monitored and proactive.
Important things that you need to know when choosing a Generator rental supplier
- Check if the Generator is genuine or not? Make sure the generator is not an old imported from abroad.
- Does the machine guarantee 100% capacity?
- After-sales service (maintenance)
- Prestige, quality, partner of big brands
- Highly specialized mechanic team
Rental Generator price in Vietnam
As mentioned to you, currently on the market there are too many “Generator rental service” providers in Vietnam. Generator rental prices are high or low depending on the brand, model, origin, current status…
We do not guarantee to bring the cheapest price, because quality always goes hand in hand with price. But we are committed to offering the most reasonable price, worthy of the quality of our equipment and services.
To get preferential prices, please leave us your contact information.
Our Generator models for rent
Shindaiwa DGW310MC (9.9 kVA)
Specification
Model | DGW310MC | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 9.9 | |
kw | 8.0 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | 400 | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 15.9/1,500 |
kW/min-1 | 14.0/1,500 | ||
Fuel consumption (75%) | l/h | 3.0 | |
Fuel tank capacity | l | 37 | |
Dimension (Length x Width x Height) | mm | 1,410 x 760 x 566 | |
Dry weight | kg | 333 |
Denyo DCA25ESK and Airman SDG25 (20 kVA)
Specification
Model | DCA25ESK | SDG25S | ||
Alternator | Frequency | Hz | 50 | |
Output rating | kVA | 20 | ||
kw | 16 | |||
No.of phase | 3-Phase, 4-Wire | |||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | SINGLE Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | |||
Engine | Output rating | PS/rpm | 25/1,500 | 26/1,500 |
kW/min-1 | 18.4 | 19.1 | ||
Fuel consumption (75%) | l/h | 3.9 | 4.0 | |
Fuel tank capacity | l | 62 | 70 | |
Dimension (Length x Width x Height) | mm | 1,540 x 650 x 900 | 1,550 x 700 x 980 | |
Dry weight | kg | 591 | 610 |
Denyo DCA45ESI (37 kVA)
Specification
Model | DCA45ESI | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 37 | |
kw | 29.6 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 46.5/1,500 |
kW/min-1 | 34.2/1,500 | ||
Fuel consumption (75%) | l/h | 6.3 | |
Fuel tank capacity | l | 100 | |
Dimension (Length x Width x Height) | mm | 1,900 x 880 x 1250 | |
Dry weight | kg | 960 |
Airman SDG45 (37 kVA)
Model | SDG45S | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 37 | |
kw | 29.6 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 51.7/1,500 |
kW/min-1 | 38/1,500 | ||
Fuel consumption (75%) | l/h | 6.4 | |
Fuel tank capacity | l | 100 | |
Dimension (Length x Width x Height) | mm | 1,870 x 860 x 1,220 | |
Dry weight | kg | 960 |
Denyo DCA60ESI (50 kVA)
Specification
Model | DCA60ESI | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 50 | |
kw | 40 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 66/1,500 |
kW/min-1 | 48.5/1,500 | ||
Fuel consumption (75%) | l/h | 8.8 | |
Fuel tank capacity | l | 125 | |
Dimension (Length x Width x Height) | mm | 2,050 x 880 x 1,250 | |
Dry weight | kg | 1,240 |
Airman SDG60S (50 kVA)
Specification
Model | SDG60S | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 50 | |
kw | 40 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 65.4/1,500 |
kW/min-1 | 48.1/1,500 | ||
Fuel consumption (75%) | l/h | 8.6 | |
Fuel tank capacity | l | 135 | |
Dimension (Length x Width x Height) | mm | 2,090 x 860 x 1,220 | |
Dry weight | kg | 1,120 |
Denyo DCA100ESI (80 kVA)
Model | DCA100ESI | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 80 | |
kw | 66.4 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 100/1,500 |
kW/min-1 | 73.6/1,500 | ||
Fuel consumption (75%) | l/h | 13.5 | |
Fuel tank capacity | l | 225 | |
Dimension (Length x Width x Height) | mm | 2,750 x 1,050 x 1350 | |
Dry weight | kg | 1,730 |
Airman SDG100S (80 kVA)
Model | SDG100S | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 80 | |
kw | 66.4 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 100/1,500 |
kW/min-1 | 73.6/1,500 | ||
Fuel consumption (75%) | l/h | 14.5 | |
Fuel tank capacity | l | 225 | |
Dimension (Length x Width x Height) | mm | 2,600 x 1,000 x 1,400 | |
Dry weight | kg | 1,640 |
Denyo DCA125SPK3 (100 kVA)
Model | DCA125SPK3 | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 100 | |
kw | 83 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 133/1,500 |
kW/min-1 | 97.8/1,500 | ||
Fuel consumption (75%) | l/h | 15.5 | |
Fuel tank capacity | l | 250 | |
Dimension (Length x Width x Height) | mm | 3,100 x 1,080 x 1,500 | |
Dry weight | kg | 2,120 |
Airman SDG150S (125 kVA)
Specification
Model | SDG150S | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 125 | |
kw | 100 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 160/1,500 |
kW/min-1 | 118/1,500 | ||
Fuel consumption (75%) | l/h | 19.4 | |
Fuel tank capacity | l | 250 | |
Dimension (Length x Width x Height) | mm | 2,990 x 1,180 x 1,480 | |
Dry weight | kg | 2,180 |
Denyo DCA150 (125 kVA)
Specification
Model | DCA150 | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 125 | |
kw | 100 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 153/1,500 |
kW/min-1 | 113/1,500 | ||
Fuel consumption (75%) | l/h | 20.6 | |
Fuel tank capacity | l | 250 | |
Dimension (Length x Width x Height) | mm | 3,250 x 1,080 x 1,500 | |
Dry weight | kg | 2,390 |
Airman SDG220S (200 kVA)
Specification
Model | SDG220S | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 200 | |
kw | 166 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 246/1,500 |
kW/min-1 | 181/1,500 | ||
Fuel consumption (75%) | l/h | 31.8 | |
Fuel tank capacity | l | 390 | |
Dimension (Length x Width x Height) | mm | 3,700 x 1,300 x 1,670 | |
Dry weight | kg | 3,630 |
Denyo DCA220ESK (200 kVA)
Specification
Model | SDG220ESK | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 200 | |
kw | 166 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 237/1,500 |
kW/min-1 | 178/1,500 | ||
Fuel consumption (75%) | l/h | 31.9 | |
Fuel tank capacity | l | 380 | |
Dimension (Length x Width x Height) | mm | 3,700 x 1,300 x 1,750 | |
Dry weight | kg | 3,770 |
Denyo DCA300SPK3 (270 kVA)
Specification
Model | DCA300SPK3 | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 270 | |
kw | 216 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 316/1,500 |
kW/min-1 | 232/1,500 | ||
Fuel consumption (75%) | l/h | 43.6 | |
Fuel tank capacity | l | 490 | |
Dimension (Length x Width x Height) | mm | 3,750 x 1,400 x 1,800 | |
Dry weight | kg | 4,160 |
Airman SDG300S (270 kVA)
Specification
Model | SDG300S | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 270 | |
kw | 216 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 315/1,500 |
kW/min-1 | 232/1,500 | ||
Fuel consumption (75%) | l/h | 43.1 | |
Fuel tank capacity | l | 490 | |
Dimension (Length x Width x Height) | mm | 3,900 x 1,400 x 1,760 | |
Dry weight | kg | 3,790 |
Airman SDG400S (350 kVA)
Specification
Model | SDG400S | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 350 | |
kw | 280 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 421/1,500 |
kW/min-1 | 310/1,500 | ||
Fuel consumption (75%) | l/h | 56.6 | |
Fuel tank capacity | l | 490 | |
Dimension (Length x Width x Height) | mm | 4,150 x 1,400 x 2,040 | |
Dry weight | kg | 5,120 |
Denyo DCA400SPMII (350 kVA)
Specification
Model | DCA400SPMII | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 350 | |
kw | 280 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 421/1,500 |
kW/min-1 | 310/1,500 | ||
Fuel consumption (75%) | l/h | 52.1 | |
Fuel tank capacity | l | 490 | |
Dimension (Length x Width x Height) | mm | 4,200 x 1,400 x 2,100 | |
Dry weight | kg | 5,420 |
Denyo DCA600SPK (554 kVA) / DCA610SPM (554 kVA)
Specification
Model | DCA600SPK | DCA610SPM | ||
Alternator | Frequency | Hz | 50 | |
Output rating | kVA | 554 | ||
kw | 450 | |||
No.of phase | 3-Phase, 4-Wire | |||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | ||
Power factor | 0.8 (Lagging) | |||
Engine | Output rating | PS/rpm | 640/1,500 | 700/1,500 |
kW/min-1 | 470/1,500 | 517/1,500 | ||
Fuel consumption (75%) | l/h | 81.8 | 82 | |
Fuel tank capacity | l | 490 | 490 | |
Dimension (Length x Width x Height) | mm | 5,580 x 1,650 x 2,400 | 5,280 x 1,650 x 2,400 | |
Dry weight | kg | 8,860 | 8,700 |
Denyo DCA800SPK (700kVA)
Specification
Model | DCA800SPK | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 700 | |
kw | 560 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 190~215(220) or 380~430(440) | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | |
kW/min-1 | 613/1,500 | ||
Fuel consumption (75%) | l/h | 102 | |
Fuel tank capacity | l | 490 | |
Dimension (Length x Width x Height) | mm | 6110 x 1950 x 2500 | |
Dry weight | kg | 11,200 |
UPR1250 (1250 kVA)
Specification
Model | UPR1250 | ||
Alternator | Frequency | Hz | 50 |
Output rating | kVA | 1250 | |
kw | 1000 | ||
No.of phase | 3-Phase, 4-Wire | ||
Rated Voltage | V | DUAL Voltage System Line 380~480 | |
Power factor | 0.8 (Lagging) | ||
Engine | Output rating | PS/rpm | 1,500/1,500 |
kW/min-1 | 1,227/1,500 | ||
Fuel consumption (75%) | l/h | 199 | |
Fuel tank capacity | l | 1,000 | |
Dimension (Length x Width x Height) | mm | 6,060 x 2,440 x 2,600 | |
Dry weight | kg | 20,000 |